Get NCP-MCI-6.5 Braindumps & NCP-MCI-6.5 Real Exam Questions [Q29-Q49]

Share

Get NCP-MCI-6.5 Braindumps & NCP-MCI-6.5 Real Exam Questions

Nutanix NCP-MCI-6.5 Actual Questions and Braindumps

NEW QUESTION # 29
Which two access protocols are supported by Files? (Choose two.)

  • A. FCOE
  • B. ISCSI
  • C. NFS
  • D. SMB

Answer: C,D


NEW QUESTION # 30
Refer to Exhibit.

An administrator increases the cluster RF to 3. The containers are not modified.
What will the new values in the data resiliency dashboard be for FAILURES TOLERABLE for the Zookeeper and Extent Groups components?

  • A. Zookeeper = 1 and Extent Groups = 1
  • B. Zookeeper = 2 and Extent Groups = 1
  • C. Zookeeper = 2 and Extent Groups = 2
  • D. Zookeeper = 1 and Extent Groups = 2

Answer: B

Explanation:
According to the web search results, the cluster redundancy factor (RF) determines how many copies of the cluster metadata and configuration data are stored on different nodes. By default, the cluster RF is 2, which means that there are three copies of the Zookeeper and Cassandra data on the cluster. If the cluster RF is increased to 3, then there will be five copies of the Zookeeper and Cassandra data on the cluster12. This means that the Zookeeper component can tolerate two failures, as it can still operate with a quorum of three nodes out of five3.
However, the container replication factor (RF) determines how many copies of the VM data and oplog are stored on different nodes. The container RF can be set independently for each container, and it can be different from the cluster RF. For example, a container can have RF 2 even if the cluster has RF 34. In this case, the container will only have two copies of the VM data and oplog on the cluster, regardless of the cluster RF. This means that the Extent Groups component can only tolerate one failure, as it needs at least one copy of the VM data and oplog to be available5.
Therefore, if the administrator increases the cluster RF to 3, but does not modify the containers, then the new values in the data resiliency dashboard will be Zookeeper = 2 and Extent Groups = 1.


NEW QUESTION # 31
An administrator was reviewing various AOS logs when a it was noticed that the time of the logs were off by several hours.
Which initial step was missed during the post process cluster configuration?

  • A. Setting the cluster time zone via PE GUI
  • B. Setting the cluster time zone via PC GUI
  • C. Setting the cluster time zone via CVM ACLI
  • D. Setting the cluster time zone via CVM NCLI

Answer: D

Explanation:
The cluster time zone is a setting that determines the time zone used by all CVMs in the cluster. The cluster time zone affects the timestamps of Nutanix logs, events, alerts, and reports. The cluster time zone also affects the scheduling of tasks such as snapshots, replication, and upgrades. By default, the cluster time zone is set to UTC (Coordinated Universal Time) when the cluster is created3.
To change the cluster time zone, the administrator needs to use the ncli (Nutanix command-line interface) on any CVM in the cluster. The steps are as follows4:
Log in to any CVM using SSH.
Run ncli cluster get-timezone to check the current cluster time zone.
Run ncli cluster set-timezone timezone=<timezone> to change the cluster time zone, where <timezone> is a valid time zone identifier (for example, America/New_York).
Run ncli cluster get-timezone again to verify that the cluster time zone has been changed.
Note that changing the cluster time zone does not affect the time zone of Prism Element or Prism Central VMs. To change their time zone, the administrator needs to use Prism Element UI or Prism Central UI respectively5.


NEW QUESTION # 32
What is the expected operation during node addition when the new node has a different AOS version?

  • A. The node is automatically re-imaged using the software currently running in the cluster.
  • B. The addition fails and forces the administrator to image using standalone Foundation.
  • C. The node is added and a separate upgrade operation must be performed.
  • D. The entire cluster is upgraded to the latest one-click release.

Answer: A

Explanation:
The node is automatically re-imaged using the software currently running in the cluster. This is because Nutanix supports a feature called Auto Re-Image that allows adding nodes with different AOS versions to an existing cluster without manual intervention. The Auto Re-Image feature detects the AOS version mismatch and automatically downloads and installs the same AOS version as the cluster on the new node. This ensures that the cluster remains in a consistent state and avoids any compatibility issues.


NEW QUESTION # 33
An administrator is commissioning a Nutanix Enterprise Cloud. Once the user VMs have been deployed and are running, the administrator finds that VMs on the same host are able to communicate, but are unable to communicate between hosts.
What must be changed to enable full inter-VM communications?

  • A. Update the switch to specifically allow VLAN 15
  • B. Change the spanning-tree port type on the switch.
  • C. Change the network the VMs are connected to
  • D. The VMs need to have static IP addresses.

Answer: A

Explanation:
According to the web search results, one possible cause of inter-VM communication failure between hosts is that the switch is not configured to allow VLAN 15 traffic. VLAN 15 is the default VLAN ID used by AHV for internal communication between CVMs and hosts. If the switch blocks or drops VLAN 15 packets, it will prevent inter-VM communication across hosts4. To enable full inter-VM communication, the administrator should update the switch to specifically allow VLAN 15 traffic on the ports connected to the AHV hosts.


NEW QUESTION # 34
An administrator is concerned about the amount of data that a VM reading and writing to the storage fabric.
Which metric will provide that data?

  • A. VM Storage Controller Bandwidth
  • B. VM Storage Controller IOPS
  • C. Host Hypervisor IO Bandwidth
  • D. Host Disk IOPS

Answer: B


NEW QUESTION # 35
Refer to the exhibit.

Which two initial cluster configuration tasks were missed during the deployment process? (Choose two.)

  • A. Host password changes
  • B. BIOS password changes
  • C. Password policy changes
  • D. CVM password changes

Answer: A,D


NEW QUESTION # 36
Which two permission assignment tasks can be accomplished via Prism Element? (Choose two.)

  • A. Grant a user permission to create and delete snapshots on a specific VM
  • B. Grant a user permission to view details of all VMs on a specific cluster
  • C. Grant an active directory group permission to perform back operations
  • D. Grant a user permission to create VMs on a specific storage container

Answer: A,B

Explanation:
Prism Element is a management interface that allows administrators to assign permissions to users and groups on a per-cluster, per-VM, or per-storage container basis.
https://www.nutanix.com/content/dam/nutanix/resources/support/ncp-mci-ds.pdf


NEW QUESTION # 37
During an AHV upgrade, an administrator finds that a critical VM was powered off rather than migration to another host.
Which scenario explains this behavior?

  • A. NO AHV hosts were able to be scheduled.
  • B. The VM was on the same host as the acropolis leader.
  • C. The VM was marked as an agent VM.
  • D. The VM OS hung during migration.

Answer: C


NEW QUESTION # 38
An administrator is tasked with configuring networking on an AHV cluster and needs to optimize for maximum single VM throughput.
Which bond mode should the administrator select?

  • A. Active-Active
  • B. No Uplink Bond
  • C. Active-Active with Mac pinning
  • D. Active-Backup

Answer: A

Explanation:
Active-Active is a bond mode that allows all uplinks in the bond to be used simultaneously for traffic transmission and reception. This bond mode provides load balancing and increased bandwidth for the AHV host and its VMs. Active-Active bond mode uses a hashing algorithm based on source MAC addresses to distribute traffic across different uplinks in the bond. Each individual VM NIC uses only a single bond member interface at a time, but multiple VM NICs are spread across different bond member interfaces. As a result, it is possible for a Nutanix AHV node with two 10 Gb interfaces to use up to 20 Gbps of network throughput, while individual VMs have a maximum throughput of 10 Gbps6.
Therefore, if an administrator needs to optimize for maximum single VM throughput, they should select Active-Active bond mode for their AHV cluster. This bond mode can be configured using Prism Element UI or manage-ovs commands on each AHV host7. No additional configuration is required on the upstream switch side, as long as the switches are interconnected physically or virtually and both uplinks trunk the same VLANs8.


NEW QUESTION # 39
An administrator needs to relocate an AHV cluster to a new datacenter during a maintenance window. The cluster will use the same IPs in the new datacenter.
Which two steps should be taken to prepare for this task? (Choose two.)

  • A. Relocate the linked LDAP server
  • B. Stop all Nutanix Files clusters
  • C. Reconfigure IPMI for the new datacenter
  • D. Shut down all user VMs in the cluster

Answer: B,D

Explanation:
According to the web search results, two steps that should be taken to prepare for relocating an AHV cluster to a new datacenter during a maintenance window are:
Shut down all user VMs in the cluster: This step is necessary to ensure that there is no data loss or corruption during the relocation process. The user VMs can be shut down either individually or in bulk by using the Prism Element web console or the acli command-line interface1.
Stop all Nutanix Files clusters: If the AHV cluster hosts any Nutanix Files clusters, they should be stopped before relocating the cluster. Nutanix Files clusters are composed of one or more virtual machines that provide file services to clients. Stopping a Nutanix Files cluster will stop all the file server VMs and release the resources they consume2. The Nutanix Files clusters can be stopped by using the Prism Element web console or the ncli command-line interface3.


NEW QUESTION # 40
An administrator wants to reduce the largest amount of alert emails received from Prism Central.
Which two settings should the administrator customize to meet this requirement? (Choose two)

  • A. Skip empty digest email
  • B. Dally Digest
  • C. Email Recipients
  • D. Every Single Alert

Answer: B,C

Explanation:
According to the Nutanix Support & Insights website1, you can configure alert emails through Prism Central by enabling or disabling customer email notification for each alert. You can also modify or create custom alert policies for different entities and clusters23.


NEW QUESTION # 41
An administrator wants to expand the Failure Domain level of a cluster.
What two options are available? (Choose two.)

  • A. Block
  • B. Node
  • C. Data Center
  • D. Rack

Answer: A,D


NEW QUESTION # 42
A newly-hired Nutanix administrator was tasked by the CIO to create a single VM on a test network. The network administrator stated that a native VLAN was used on the Cisco TOR switches with the following parameters:
IP address:172,16.1.2
Network Mask: 255.255.255.0
Default gateway: 172.16.1.1
VLAN:1
The same parameters were used to create a network profile on Nutanix, but the when the VM was on ...
What should the Nutanix administrator do to fix this issue?

  • A. Enable IPv6 on the VM.
  • B. Change VLAN field from vlan. 1 to vlan.0.
  • C. Nutanix removed support for native VLAN.
  • D. Use DHCP as opposed to static IP

Answer: B

Explanation:
A native VLAN is a VLAN that is assigned to untagged traffic on a trunk port of a switch. A trunk port can carry traffic from multiple VLANs, but it needs to have a native VLAN to handle traffic that does not have a VLAN tag. The native VLAN is usually VLAN 1 by default on most switches, but it can be changed to any other VLAN number2. When creating a network profile on Nutanix, the administrator needs to specify the VLAN ID that matches the VLAN configuration on the physical switch. However, if the network profile uses the same VLAN ID as the native VLAN on the switch, it will cause network connectivity issues for the VMs connected to that network profile. This is because Nutanix AHV uses 802.1Q tagging for all network traffic, including traffic in the native VLAN. The switch will expect untagged traffic in the native VLAN and will drop any tagged traffic in that VLAN3. To fix this issue, the administrator needs to change the VLAN field from vlan. 1 to vlan. 0 in the network profile on Nutanix. This will tell Nutanix AHV to send untagged traffic for that network profile and match the native VLAN configuration on the switch4.


NEW QUESTION # 43
Async DR is configured between two sites. A network outage occurs at the primary site.
Which steps must the administrator perform to bring the VMs back into service at the backup site?
Item instructions: For each procedure, indicate the order in which that procedure must take place to meet the item requirements. Not all procedures are valid. Identify any invalid procedures using the drop-down option.

Answer:

Explanation:


NEW QUESTION # 44
An administrator needs to configure a new subnet on an AHV cluster and want to ensure that VMs will automatically be assigned an IP address at creation time.
Which type of network does the administrator need to create?

  • A. DHCP Network
  • B. Managed Network
  • C. Dynamic Network
  • D. Unmanaged Network

Answer: B


NEW QUESTION # 45
An administrator is performing validation testing of a new-deploy cluster. During this test, the administrator disconnect each LAN interface from each of the nodes while pinging the hypervisor and guest VMs.
When the first interface is disconnected, pings continue as expected to the hypervisor, but pings stop responding from the guest. Pings continue when the interface is reconnected. When the second interface is disconnected, pings continue to both the hypervisor and guest VMs.
What could be the cause of this error?

  • A. Portfast is not enabled on the switch ports
  • B. This is normal behavior for a LAN Failover
  • C. Switch ports are configured with different VLANs
  • D. One of the network interfaces has a bad patch cable.

Answer: C


NEW QUESTION # 46
An administrator needs to run a mixed Exchange and SQL workload with a guaranteed amount of container space for each application.
How should the administrator meet this requirement?

  • A. Create two containers and reserve space for vDisks
  • B. Create two containers and reserve space for containers
  • C. Create one container and set capacity reservation
  • D. Create one container and enable compression

Answer: A


NEW QUESTION # 47
Which two capabilities does IPAM provide in a Nutanix networking configuration? (Choose two.)

  • A. Configures a VLAN with an IP subnet and assigns a group of IP addresses
  • B. Allows proxy server settings to be set up for a defined network
  • C. Configures firewall rules to prevent or allow certain TCP/IP traffic
  • D. Allows AHV to assign IP addresses automatically to VMs using DHCP

Answer: A,D


NEW QUESTION # 48
An administrator is setting up a Nutanix cluster and needs to configure the default VLAN.
Which configuration should the administrator choose?

  • A. Vlan.2
  • B. Vlan.1
  • C. Vlan.7
  • D. Vlan.0

Answer: B

Explanation:
Nutanix cluster is a group of Nutanix nodes that share data and resources across a network1. A VLAN is a virtual LAN that allows devices on different physical LANs to communicate as if they were on the same network2.
by default, a virtual NIC (VM NIC) on a guest VM operates in access mode and can send and receive traffic only over its own specified VLAN. The default VLAN ID for access mode interfaces is 1.
Therefore, by choosing Vlan.1 as the default VLAN, you can simplify the network configuration and avoid potential issues with other VLAN IDs.


NEW QUESTION # 49
......


Nutanix NCP-MCI-6.5 certification exam is an excellent way for IT professionals to demonstrate their expertise in multicloud infrastructure management and validate their skills and knowledge in this area. By obtaining this certification, individuals can enhance their career prospects, gain recognition in the industry, and contribute to the success of their organizations.


Upon passing the NCP-MCI-6.5 exam, candidates will receive the Nutanix Certified Professional - Multicloud Infrastructure (NCP-MCI) v6.5 certification. Nutanix Certified Professional - Multicloud Infrastructure (NCP-MCI) v6.5 exam certification is valid for two years and can be renewed by passing a recertification exam. Nutanix Certified Professional - Multicloud Infrastructure (NCP-MCI) v6.5 exam certification demonstrates the candidate's expertise in managing Nutanix clusters and provides recognition in the IT industry. It also opens up new career opportunities and enhances the candidate's earning potential.

 

NCP-MCI-6.5 Dumps To Pass Nutanix Exam in 24 Hours - DumpsValid: https://www.dumpsvalid.com/NCP-MCI-6.5-still-valid-exam.html

Buy Latest NCP-MCI-6.5 Exam Q&A PDF - One Year Free Update: https://drive.google.com/open?id=1H9x8Ggtf961aSCTiWM9mxO-nOvJkfAll